| Coadot A6 plus |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Special Features |
|
|
|
|
|
| Measurement |
| Clotting, chromogenic, immunological |
| Quarter test volume (75μL) |
| High speed testing |
| Biphasic waveform analysis |
| Profile testing in batch or random access |
| Preset for 9 different profiles |
| Single or double determination |
| Automatic reflex testing |
|
|
|
|
|
| Sample |
| 3 x 15 primary tubes |
| Positive sample identification (ID and rack
position ) with barcode |
| Cap Piercing for BD Vaccutainer ® or
Sarstedt Monovette ®. |
| Micro tubes like Eppendorf ®
2mL for
pediatric samples |
| Emergency STAT position |
| Sample continous loading in random
access mode |
|
|
|
|
|
| System |
| 6 optic channels at 405nm with auto light sensing and extraneous light elimination to reduce interferences such like bilirubin or sunlight |
| Dual-Z pipetting system with two probes and liquid level sensor |
| Integrated laser barcode reader for samples and reagent |
| Bi-directional Interface for PC-Link to LIS. |
| Integrated graphical thermal printer |
| Heated and cooled positions for reagents,
controls, buffers |
| Integrated drawers for consumables |
| System configuration as 'OPEN' or 'CLOSED' |
| Longlife Service Interval (every 100.000 tests) |
|
|
|
|
|
| Quality Control |
| Onboard positions for up to 3 control plasma |
| Auto QC flagging for errorneous results |
| One click report with Levey-Jennings graph
and Westgard analysis |
| LOT. number (control + reagent) specific
QC analysis is possible |
|
|
|
|
|
| Software |
| An intuitive EUROLyser familiar graphical user interface |
| Multi language dialogue (En, Ger, Sp, It, China, Greek, Russia) |
| Free programmable test protocols to change or adapt new tests |
| Calculation of activity %, INR, Ratio, g/L, mg/dL and more |
| Calibration curve can be identified with up to 6 points per test |
| Touchscreen Control (supported) |
|
|
|
|
|
| Special Functions |
| Automatic plasma dilutions up to 1:100 |
| Automatic test calibration routines |
| Automatic test skip, if reagent run out |
| Database for 1 Mio patient history |
| Test calibration management for each reagent
lot |
| Each result can be traced back to reagent lot
and calibration data |
| Patient monitoring for long time periods |
| Reaction curve monitoring |
|
|
|
|
|
| Economic |
| Quarter test volume to 75% cost savings |
| Reagent dead volume is below 200 μL |
| Very economic consumption of rinse
andcleaning solution |
| All critical system parameters are monitored
and make the Instrument nearly free of service |
|
|
|
|
|
| Global |
| PT, aPTT, Thrombintime, Fibrinogen (Clauss & PT derived) Heparin |
|
|
|
|
|
| Factors |
| Factor II, V, VII, VIII, IX, X, XI, XII |
|
|
|
|
|
| Thrombophilia |
| Protein C, Protein S & free Protein-S, Factor V Leiden (APC-R), Antithrombin, D-Dimer & FDP, LA Screen (DRVVT), LA Confirm (DRVVT), Plasminogen |
|
|
|
|
|
| Calculated Units |
| Activity %, Ratio, Polish ratio, INR (ISI system or INR calibration curve), g/L, mg/dL, ng/L, ng/mL, μg/L, IU/mL |
|
|
|
|
|
|
|
|
|
|
| back to: Instruments |